1.Temperature Measuring Range: 0-99℃
2.Temperature Measurement Accuracy: ±0.1℃
3.Humidity Measurement Range: 0—99%RH
4.Humidity Accuracy: ±3%RH
5.Number of signal-output: 7, (over-temperature, temperature control, insufficient temperature, egg left-turning, egg right-turning, humidity control, alarm)
6.The maximum output load current: temperature control, insufficient temperature ≤ 8A/AC220V, over-temperature, egg left-turning, egg right-turning, humidity control, alarm ≤ 1A / AC22
7.Number of egg-turning: the maximum record is 999 times.
8.cycle of egg-turning: adjustment of 0 – 999 minutes (the factory default is 90 minutes)
9.egg-turning time: adjustment from 0 to 999 seconds (the factory default is 180 seconds)
10.ventilation cycle: from 0 to 999 minutes
(the factory default is 120 minuteS
11.vetilation time: from 0 to 999 seconds (the factory default is 30 seconds)
12.Temperature measurement length: About 2 meters